Beijing Taktvoll ES-300D new generation intelligent electrosurgical generator

Beijing Taktvoll ES-300D new generation intelligent electrosurgical generator has manual mode and intelligent mode. It can bring convenience to the surgeon and reduce surgical damage. It is particularly suitable for endoscopy, gastroenterology, gynecology, urology, pediatrics and other departments that have high standards for output control of electrocautery and high energy output.

It is a universal multifunctional surgical equipment with 10 working modes, including 4 monopolar cutting modes, 3 monopolar coagulation modes, and 3 bipolar modes.

Two monopolar output ports

4 monopolar cutting modes: pure cut, blend 1, blend 2, blend 3.

3 coagulation modes: spray coagulation, forced coagulation, and soft coagulation

3 bipolar output modes: macro mode, standard mode, fine mode.

CQM contact quality monitoring system

Simultaneous cutting and coagulation

Electrosurgical pens and foot switch control

Start with the recently used mode, power and other parameters

9 sets of memory modes, power parameters, etc., can be quickly recalled.

Volume adjustment function

Cut and coagulate in an intermittent manner

The monopolar mode of the device includes monopolar cutting and monopolar coagulation. The bipolar mode includes macro mode, standard mode and fine mode. The output power is adjustable.

monopolar mode- monopolar cutting

Monopolar cutting mode includes pure cut, blend 1, blend 2, blend 3. The output power can be adjustable.

Pure cut: cut the tissue cleanly and accurately without coagulation

blend 1: Use when the cutting speed is slightly slow and a small amount of hemostasis is required.

blend 2: Compared with blend 1, it is used when the cutting speed is slightly slower and the better hemostatic effect is needed.

blend 3: Compared with blend 2, it is used when the cutting speed is slower and the much better hemostatic effect is needed.

Monopolar modes- monopolar coagulation

Monopolar coagulation mode includes spray coagulation, forced coagulation and soft coagulation, and the output power is adjustable.

spray coagulation: high-efficiency coagulation without contact surface. The coagulation depth is shallow. The tissue is
                               removed by evaporation. It usually use a Blade or ball electrode for coagulation.

forced coagulation: It’s non-contact coagulation. The output threshold voltage is lower than spray coagulation. It’s suitable
                                for coagulation in a small area.

soft coagulation: Mild coagulation penetrates deeply to prevent tissue carbonization and reduce electrode adhesion to tissue.

Bipolar mode

The bipolar mode includes macro mode, standard mode, fine mode. The output power is adjustable.

Macro mode: It’s used in bipolar cutting or rapid coagulation. Voltage is higher and the power is higher
                      than standard and fine mode.

Standard mode: It’s suitable for most bipolar applications. Keep the low voltage to prevent sparks.

Fine mode: It’s used for high precision and fine control of drying amount. Keep the low voltage to prevent sparks.

1Be able to use two electrosurgical pens to achieve simultaneous cutting and coagulation
Independent manual control ports and control output ports support simultaneous cutting and coagulation of multiple points during operation to meet
           more surgical needs, such as cardiac bypass.

2Great bipolar function
It has the macro-bipolar function of blocking large blood vessels, and the precision bipolar function of the spark suppression technology. The bipolar
           output power is up to 150W.

3Unique low voltage design
It is suitable for tissue cutting under high-impedance environment. It can achieve excellent cutting effect with lower power. It can be used for urological
           surgery for prostate gasification and gynecological hysteroscopy.

4Memory function
9 memory units can store doctors' different operating habits, and can be quickly switched or recalled during the operation.

5Universal endoscope port
Various endoscopes or surgical accessories can be connected.

6Accurate contact quality monitoring system (CQM)
Automatically monitor the quality of contact between the dispersive pad and the patient in real time. If the contact quality is lower than the set value,
           there will be a sound and light alarm and cut off the power output to ensure safety.

7Can be used with various laparoscopes for cutting and coagulation
All can be connected with cystoscope, arthroscopy, laparoscope, thoracoscopy, hysteroscope, etc., providing a source of cutting and coagulation. All
           can cooperate with cystoscope to perform prostate gasification resection.

8High frequency and low frequency leakage current monitoring system
The high-frequency leakage current is lower than150mA and the low-frequency leakage current is lower than 10uA. The effective output efficiency ratio
           of electrocautery is greater or equal to 95.

9To start with monopolar electrosurgical pen control or foot switch control, bipolar foot switch control
It can be selected according to the surgeon's personal habits.

103 windows LCD digital display
Digital display of output power, with different acousto-optic display during output.

11Using CPU double closed loop to control power output
Once the power output deviates from the safe setting, the CPU control circuit will cut off the output of the electrosurgical generator.

12Simple to use
One-button operation for cutting and coagulation. Large digital screen display make the device intuitive and convenient.

*Electrosurgical generator belongs to surgical products, and its contraindications are related to the type of electrosurgery performed. The device itself has no absolute contraindications. Patients with implantable cardiac pacemakers or other metal implants should be careful to avoid high-frequency current paths flowing near the implant.

Product Specifications